Numerical Modelling Of Thermoacoustic Heat Pumps And Engines (2014. 104 S. 220 mm)

108.57 SGD
Member Price
97.72

Product Description

§16§Thermoacoustic systems with no stacks or intermittent stacks represent a promising alternative to conventional stack-based systems. There is theoretical and experimental evidence that such systems can perform more efficiently and produce more acoustic power than thermoacoustic systems with an array of flat plates or regular pores. As opposed to conventional thermoacoustic systems, no-stack setups do not include porous material as a medium for storing and transferring heat. In such systems, heat is transported by gas parcels directly between heat exchangers. A simplified Lagrangian model has been developed in this work to approximately analyze no-stack standing-wave thermoacoustic configurations. More accurate simulations of favorable configurations are investigated with the help of computational fluid dynamics (CFD). Using CFD code FLUENT, more efficient setups were found with the second law efficiency up to 55%. The dependence of system performance is reported for a range of syst §16§em parameters. A good agreement between the simplified model and CFD results was achieved in most cases.

Available to Order

Usually dispatches within 3-4 weeks

While every attempt has been made to ensure stock availability, occasionally we may run out of stock at our stores.